No NIL-No Name of NIL Holder Status Authorised Action Location Province
1 NIL-04 (Rev 2) Necsa Issued in April 2025 Manufacturing of component and construction activities related to the extension of Thabana Pipe Store facility. Pelindaba site Gauteng

Facility/Activity InspectedDate of InspectionAim of InspectionSummary of Inspection outcomes
UMET (NIL09)9-Apr-25Planned and unannounced inspection addressing –
(i)    Limits and Conditions of Operation
(ii)   Radiation Protection
(iii) Emergency Planning and Preparedness
(iv) LC in Part B of the Nuclear Licence
Three (3) findings and one observation were raised
SAFARI-1 Research Reactor – (NIL-02)14-Apr-25Planned and announced inspection addressing compliance with Maintenance Schedules (RR-MPR-0002, RR-MPR-0003, RR-MPR-0004, RR-MPR-0005) and Operating Technical Specifications (RR-VSK-1000) during the reactor shutdown.There were no findings raised during the inspection. The authorisation holder was found to be compliant with all aspects evaluated during the inspection
A-West Drum Store (NIL-07)15-Apr-25Planned and announced inspection addressing –
(i)  Radiation Protection
(ii) Limits and Conditions on Operation
(iii)   Decommissioning
(iv)   Funding for Decommissioning and Radioactive Waste
(v)   Organisational Capability and Management of Organisational Change
(vi)   Public Safety Information Forum
(vii) Implementation of Written Instruction for all Operations that may Affect Nuclear Safety
(viii)    Radiation safety or Nuclear Security
There were no findings raised during the inspection. The authorisation holder was found to be compliant with all aspects evaluated during the inspection
Area 74 Labs (NIL-10) 12-May-25Planned and announced inspection addressing –
(i)      Radiation Protection
(ii)    Limits and Conditions on Operation
(iii)   Decommissioning
(iv)   Funding for Decommissioning and Radioactive Waste
(v)    Organisational Capability and Management of Organisational Change
(vi)   Public Safety Information Forum
(vii) Implementation of Written Instruction for all Operations that may Affect Nuclear Safety,
(viii)        Radiation safety or Nuclear Security
Two (2) findings were raised
Quarantine Store (NIL-12)27-May-25Planned and announced inspection addressing –
(i)    Radiological Protection
(ii)   Events (including Incidents or Accidents) on the Site
(iii) Emergency Planning and Preparedness
(iv) Safety Committee
(v)  Safety Documentation
(vii)  Display of Nuclear Installation License
(viii) Transport
(ix)    Modification to the design of the Existing Plant or Facility
There were no findings raised but one (1) observation was raised
Pel East Ponds (NIL-14)29-May-25Planned and announced inspection addressing –
(i)    Events Management
(ii)   Safety Documentation
(iii) Operating Technical Specifications
(iv) Radiological Protection
(v)  Safety Committee
There were no findings raised but one (1) observation was raised
P-1500 Labs (NIL-33)16-Apr-25Planned and unannounced inspection addressing –
(i)    Decommissioning
(ii)   Funding for Decommissioning and Radioactive Waste
(iii) Emergency Planning and Preparedness
(iv) Environmental Protections
(vi) Display of Nuclear License
Three (3) findings and one (1) observation were raised
P-1900 Labs (NIL-36)30-May-25Planned and announced Inspection addressing –
(i)    Radiological Protection
(ii)   Care and Maintenance Plan
(iii) Scope of actions
(iv) Limits and Conditions on Operations
(v)  Medical Surveillance and Health Register
(vi) Decommissioning
(vii)  HIRA
(viii) Emergency Planning and Preparedness
(ix)    Documents, records, authorities, and certificates
Four (4) findings and two (2) observations were raised
NTP (NIL-39)12-Jun-25Planned and announced Inspection addressing –
(i)    Radiological Protection
(ii)   Medical Surveillance
There were no findings raised but one (1) observation was raised
NTP (NIL-39)30-May-25Planned and announced Inspection addressing .
Examination, Inspection, Maintenance and Testing
Five (5) findings and two (2) observations were raised
LETF (NIL-41)2-Jun-25Planned and announced Inspection addressing –
(i)    Examination, Inspection, Maintenance and Testing (EIMT)
There were no findings raised but six (6) observations were raised
SAFARI-1 Research Reactor: (NIL-02)6-May-25Planned and announced Inspection addressing –
(i)    LC 7: Restrictions on dealing with the site
(ii)   LC 11: Documents, Records Authorities and Certificates
Two (2) findings and one (1) observation were raised
SAFARI-1 Research Reactor: (NIL-02)13-May-25Planned and announced Inspection addressing –
LC 22: Examination, Inspection, Maintenance and Testing
There were no findings raised during the inspection. The authorisation holder was found to be compliant with all aspects evaluated during the inspection
Area 26 (NIL-29)3-Jun-25Planned and announced Inspection addressing –
(i)    LC 3: Scope of Actions
(ii)   LC 7: Restrictions on Dealing with the Site
(iii) LC 9: Medical Surveillance and Health Register
(iv) LC 12: Events Management
(v)  LC 13: Emergency Planning and Preparedness
(vi) LC 14: Environmental Protection
(vii)  LC 30: Implementation of Written Instructions for all Operations that may affect Nuclear Safety, Radiation Safety or Nuclear Security.
There were no findings raised during the inspection. The authorisation holder was found to be compliant with all aspects evaluated during the inspection
Environmental Management Group28-May-25Planned and announced Inspection addressing –
(i)    Management of Radioactive Effluent & Discharges at the Pelindaba Site
(ii)   Management of Radioactive Emissions on the Pelindaba Site
(iii) Radiological Environmental Surveillance at Pelindaba Site & Vicinity
There were no findings raised during the inspection. The authorisation holder was found to be compliant with all aspects evaluated during the inspection
Thabana Complex (NIL-04)28-May-25Planned and unannounced Inspection addressing –
(i)    Limits and Conditions on Operations
(ii)   Events Management
There were no findings raised during the inspection. The authorisation holder was found to be compliant with all aspects evaluated during the inspection
Pelstore (NIL-11)26-May-25Planned and announced Inspection addressing –
(i)    Operating Technical Specification
(ii)   Documents and Record Management
(iii) Restrictions on Dealing with the Site.
There were no findings raised during the inspection. The authorisation holder was found to be compliant with all aspects evaluated during the inspection
P2800 (NIL-27)12-May-25Planned and announced Inspection addressing: (i)    Scope of actions that may be undertaken in the facility.
(ii)   Radiological Protection
(iii) Care and Maintenance Plan
(iv) Documents, records, authorities, and certificates
(v)  Emergency Planning and Preparedness
(vi) Environmental protection
(vii)  Decommissioning
(viii) HIRA
Three (3) findings and one (1) observation were raised
B1 Basement (NIL-42)12-May-25Planned and announced Inspection addressing:
(i)    Scope of actions that may be undertaken in the facility.
(ii)   Radiological Protection
(iii) Care and Maintenance Plan
(iv) Documents, records, authorities, and certificates
(v)  Emergency Planning and Preparedness
(vi) Environmental protection
(vii)  Decommissioning
(viii) HIRA
Five (5) findings and two (2) observations were raised
Cal Pads (NAPP-02)27-May-25Planned and announced Inspection addressing –
(i)    Radiological Protection
(ii)   Emergency Planning and Preparedness
(iii) Environmental protection
(iv) Decommissioning.
Three (3) findings were raised
UChem (NIL-03)8-May-25Planned and announced Inspection addressing –
(i)    Duly Authorised and Suitable Qualified and Experienced Persons
(ii)   Safety Committee
There were no findings raised during the inspection. The authorisation holder was found to be compliant with all aspects evaluated during the inspection
YM-Vacuum (NIL-34)12-May-25Planned and announced Inspection addressing –
(i)    Scope of actions that may be undertaken in the facility.
(ii)   Radiological Protection
(iii) Care and Maintenance Plan
(iv) Documents, records, authorities, and certificates
(v)  Emergency Planning and Preparedness
(vi) Environmental protection
(vii)  Decommissioning
(viii) HIRA
Five (5) findings were raised
RadAnal Labs (NIL-37)21-May-25Planned and announced Inspection addressing –
(i)    Scope of Actions
(ii)   Radiation Protection
(iii) Organisational Capability and Management of Organisational Change
(iv) Decommissioning
(v)  Radioactive Waste Management.
Three (3) findings were raised
Pelindaba Analytical Laboratories (NIL-40)20-May-25Planned and announced Inspection addressing –
(i)    PAL-NIL40-PRG-0001: Radiological Surveillance and Control Programme for the PAL & NFP Laboratories in Building B-E1
(ii)   Radioactive Waste Management
(iii) Environmental Protection
(iv) Events Management
Two (2) findings were raised
Emergency Services23-May-25Planned and announced Inspection addressing –
(i)    Inspection and Maintenance on Emergency Vehicles and Equipment
(ii)   Control of Inspection, Measuring and Test Equipment
(iii) Control Over Radioactive Sources
(iv) Facilities and equipment used in the ECC.
Five (5) findings were raised
Area 16 (NIL-18)19-May-25Planned and announced Inspection addressing –
(i)    Scope of actions that may be undertaken in the facility.
(ii)   Radiological Protection
(iii) Care and Maintenance Plan
(iv) Documents, records, authorities, and certificates
(v)  Emergency Planning and Preparedness
(vi) Environmental protection
(vii)  Decommissioning
(viii) HIRA
There were no findings raised during the inspection. The authorisation holder was found to be compliant with all aspects evaluated during the inspection
SAFARI-1 Research Reactor (NIL-02)4-Jun-25Planned and announced Inspection addressing -(i)    Operating Technical Specifications
(ii)   Examination of a candidate Shift Supervisor
There were no findings raised during the inspection. The authorisation holder was found to be compliant with all aspects evaluated during the inspection.
ElProd (NIL-08)29-May-25Planned and announced Inspection addressing –
(i)    OTS
(ii)   SQEP
One (1) finding was raised
A8 Decon Services (NIL-06)5-Jun-25Planned and announced Inspection addressing –
(i)    Worker Radiation Protection Programme
(ii)   Follow-up on non-compliances from previous inspections
One (1) finding and one (1) observation were raised
H-Building CAM (NIL-35)12-Jun-25Planned and unannounced Inspection addressing –
(i)    Radiological Protection
(ii)   Care and Maintenance Plan
(iii) Scope of actions
(iv) Limits and Conditions on Operations
(v)  Medical Surveillance and Health Register
(vi) Decommissioning
(vii)    HIRA
(viii)   Emergency Planning and Preparedness
(ix)      Documents, records, authorities, and certificates
Five (5) findings were raised
A8 Decon Services (NIL-06)18-Jun-25Unplanned and announced Inspection addressing –
The inspection was conducted following the reported incident from the facility
Five (5) findings were raised
De-Heeling (NIL-20)18-Jun-25Unplanned and announced Inspection addressing –
The inspection was conducted following the reported incident from the facility
Two (2) findings were raised